Panyu 2×6mm2 RRU power cable for ZTE RRU ZA-RVVP Shield 300V, we also have 2x4mm2, 2×10, 2x16mm2, 3×1.5mm2 RRU Power cable.
| Marking | ||||
| 6mm2 | ZA-RVVP 300/300V 2×6 mm2 (TCCAM) RoHS IEC60332-1 XXXXm CE | |||
| Product Description | ||||
| Rated voltage(V) | 300/300&300/500 | |||
| Rated temperature(oC) | -40~70 | |||
| Standard authentication | CE | |||
| Flame retardance | A | |||
| Cold resistance | Minimum laying temperature -20℃ The minimum use of sheath is -40℃ |
|||
| Cable used open air(Y/N) | Y | |||
| Main ref std | GB/T5023-2008 JB/T8734.5-2012 | |||
| Structure Unit(mm) | ||||
| Item sort | Std limited | |||
| Conductor material | Annealed stranded copper | |||
| AWG or section | refer to technical parameters | |||
| Conductor structure | refer to technical parameters | |||
| Insulation material | Cold resistant PVC insulation | |||
| Normal thickness of Insulation | refer to technical parameters | |||
| Minimum thickness | refer to technical parameters | |||
| Insulation diameter | refer to technical parameters | |||
| Braid material | CCAAT-15A | |||
| Jacket material | PVC | |||
| Normal thickness of Jacket | refer to technical parameters | |||
| Minimum thickness | refer to technical parameters | |||
| Cable diameter | refer to technical parameters | |||
| Braid density | ≥80% | |||
Electric characteristic of ZTE 2 core 6mm2 RRU power cable for RRU ZA-RVVP Shield 300V
| Electric characteristic | ||||
| Item sort | Std. limited | Test result | ||
| The min insulation resistance, 70 ℃ (M Ω km). | refer to technical parameters | Pass | ||
| Dielectric Strength (kV/min) | 2.0kV/5min | Pass | ||
| Max. DC resistance at 20℃ (Ω/km) | refer to technical parameters | Pass | ||
| Mechanical characteristic&Reliability | ||||
| Aging Test | Std. limited | /Testing | ||
| Insulation property | ||||
| Before Aging | Tensile Strength(Mpa) | ≥10 | Pass | |
| Elongation(%) | ≥150 | Pass | ||
| Insulation aging conditions | 80℃(±2)×168 hrs | |||
| After Aging | Tensile strength rate of change(%) | ≤ ±20 | Pass | |
| Elongation rate of change (%) | ≤ ±20 | Pass | ||
| sheath property | ||||
| Before Aging | Tensile Strength(Mpa) | ≥10 | Pass | |
| Elongation(%) | ≥150 | Pass | ||
| Sheath aging conditions | 80℃(±2)×168 hrs | |||
| After Aging | Tensile strength rate of change(%) | ≤ ±20 | Pass | |
| Eelongation rate of change (%) | ≤ ±20 | Pass | ||
| Low-temperature impact | -40℃±2 | Pass | ||
| Thermal Shock Test | 150℃(±2) * 1h | Pass | ||
| Simulated outdoor test | Meet UL1581 outdoor test | |||
RoHS
| RoHS | ||||
| Item | Value limited(ppm) | Testing | ||
| Pb | 800 | N.D | ||
| Hg | 800 | N.D | ||
| Cd | 70 | N.D | ||
| Cr6+ | 800 | N.D | ||
| PBBs | 800 | N.D | ||
| PBDEs | 800 | N.D | ||
Key technical parameters
| Insulation color | Nominal cross-sectional area | Conductor construction | Conductor diameter (Ref.) | Max. conductor DC resistance at 20℃ | Nominal insulation | Min. insulation thickness | Insulation diameter (Ref.) | Nominal oversheath thickness | Min. oversheath thickness | Overall diameter |
| thickness | ||||||||||
| mm2 | pcs/mm(±0.01) | mm | Ω/km | mm | mm | mm | mm | mm | mm | |
| Blue, black | 2×6 | 84/0.30 | 3.2 | 3.3 | 0.8 | 0.62 | 5.2±0.3 | 1.2 | 0.92 | 14.5±0.5 |
| Blue, red | 2×6 | 84/0.30 | 3.2 | 3.3 | 0.8 | 0.62 | 5.2±0.3 | 1.2 | 0.92 | 14.5±0.5 |
| Light blue, gray | 2×6 | 84/0.30 | 3.2 | 3.3 | 0.8 | 0.62 | 5.2±0.3 | 1.2 | 0.92 | 14.5±0.5 |